V2G reverse discharge causes the energy flow to reverse, and the charging station changes from a "load" to a "power source". The security strategy of the main control board cannot simply copy the charging logic, and independent designs must be added at four levels.
1、 Vehicle side: expanded from overcharge prevention to over discharge prevention
Forward charging only focuses on the upper limit, while reverse discharging must simultaneously maintain the lower limit.
The main control board needs to obtain lower cell voltage and temperature from the BMS before discharging, set the SOC working range (such as 20% -90%), and directly prohibit discharge or limit power when approaching the lower limit or when the temperature is too low.
Immediate derating and shutdown beyond the boundary is a newly added safety boundary for V2G vehicles.
2、 Grid side: Anti islanding and grid synchronization are hard thresholds
After the pile becomes a power source, if the power grid is disconnected, it will reverse power to the maintenance line.
The main control board must integrate active and passive dual anti islanding detection: actively injecting disturbance to measure grid impedance, passively monitoring overvoltage, undervoltage, and underfrequency, and shutting down within seconds after power loss.
Before grid connection, hardware lock-in is required to track the phase and frequency of the power grid in real time. If it loses synchronization, it will immediately shut down, otherwise the grid connection will be an accident instantly.
3、 Power circuit: Relays and insulation should be reconstructed according to reverse current
The original relay was designed for unidirectional current, and when it was disconnected in reverse, the direction of the arc reversed, causing accelerated contact erosion and easy adhesion.
The V2G main control board needs to be equipped with bidirectional arc resistant relays, with added contact status feedback and temperature monitoring. The electronic lock cannot be unlocked until the reverse current returns to zero.
The insulation monitoring range should also be increased from 500V DC to 1000V DC, the sampling resistor withstand voltage should be synchronously upgraded, and arc fault detection should be added to identify abnormal arcs during reverse disconnection.
4、 Safety timing and communication: discharge mode independent state machine
The software needs to add a discharge state machine in parallel with a charge state machine.
During the handshake phase, the discharge power, SOC lower limit, and cycle cost are negotiated through ISO 15118-20.
Real time BMS allowed parameters are received during discharge, and the accumulated energy and switch times of each V2G cycle are recorded for predicting relay life and early warning replacement.
Summary:
The safety strategy added by V2G to the main control board includes four lines: battery over discharge prevention, grid islanding prevention, power circuit reverse resistance, and communication negotiation discharge boundary. Each one is an independent design aimed at reversing the role of "turning piles into power sources". Without one, V2G is not a functional upgrade, but a safety downgrade.