How to determine relay adhesion on the charging pile motherboard: auxiliary contacts, current characteristics, or temperature rise combined judgment?

Conclusion: A single method is not reliable enough, and the actual design should adopt a joint judgment strategy of "pre start voltage detection as the main method, cross validation of auxiliary contacts and current characteristics, and temperature rise as a continuous monitoring supplement".

1、 Auxiliary contact: direct but not sufficient

  • The auxiliary contact is mechanically linked with the main contact, and when the main contact is stuck, the auxiliary contact remains closed, which the MCU can judge based on.

  • The advantages are directness and fast response.

  • The disadvantage is that the auxiliary contacts themselves may also wear or fail, increasing costs and wiring, and can only reflect whether they are disconnected, unable to distinguish between "adhesion" and "control signal not delivered".

  • Suitable as an auxiliary confirmation, not suitable as a standalone criterion.

2、 Current characteristics: Effective during operation, ineffective before startup

  • If the relay has issued a disconnection command during charging but the current sampling still has a value, it indicates that the contacts are stuck.

  • This is effective for detecting during operation. But before starting, it has not been powered on and the current is zero, so it cannot be determined.

  • Therefore, current characteristics can only cover "in operation" scenarios and cannot replace pre startup detection.

3、 Voltage detection before startup: the most essential criterion

  • Before each charging start, keep the relay disconnected and check if there is voltage at the output terminal.

  • If there is electricity at the output end, it indicates that the contacts have adhered and closing is prohibited.

  • This is the most direct, cost-effective, and critical 'pre launch' scenario for coverage.

  • In implementation, optocouplers or isolated sampling circuits can be used to read the output voltage when the relay is disconnected, and if there is power, adhesion can be determined.

4、 Temperature rise: slow replenishment, not used separately

  • The contact resistance of adhesive contacts increases, causing heating during current flow.

  • Temperature rise monitoring can serve as an auxiliary signal during long-term operation, triggering further inspection upon detecting abnormal temperature rise.

  • But the temperature rise response is slow and greatly affected by environmental temperature, making it impossible to detect problems before startup, and can only serve as a supplementary clue for continuous monitoring.

5、 The logic of joint judgment

  • Before starting, use voltage testing to confirm that the relay can be disconnected, otherwise starting is prohibited.

  • Continuously monitor the current during operation, and if the current does not disappear after issuing a disconnection command, determine adhesion.

  • Auxiliary contacts serve as cross validation at the mechanical level and are compared with electrical testing results.

  • As a long-term trend monitoring, temperature rise should be reported to the platform or triggered to decrease when abnormal.

  • The four signals mutually confirm each other to avoid misjudgment or omission by a single means.

Summary:

  • Voltage detection before startup is the main focus. During the operation of the current characteristic tube, auxiliary contacts are used for cross validation, and temperature rise is used as a trend supplement. Joint judgment is necessary to cover three scenarios: pre startup, during operation, and long-term degradation. Any single method has blind spots.

The communication charging pile motherboard produced by Xincheng Technology is of high quality and beautiful price. Welcome to inquire and purchase!