What does the charging station control board control: charging handshake, billing and metering, safe power outage, or platform networking?

Manage all four things, but not in parallel, but in a hierarchical manner. The control board is the execution center of the entire pile: safe power-off is the bottom line, charging handshake is the threshold, billing and metering are the ledger, and platform networking is the extension. Without any layer, the pile either cannot be used or cannot be used with confidence.

Safe power outage: Bottom line, local hardware closed-loop

  • This is the responsibility that the control board cannot outsource the most.

  • Overcurrent, leakage, overheating, abnormal grounding, and relay adhesion must be judged and cut off locally in milliseconds, and cannot wait for cloud commands.

  • Leakage protection circuit, hardware overcurrent comparator, relay driver, and status feedback are all board level hard closed loops.

  • Safe power outages do not rely on the network, and can still operate when the network is disconnected.

  • This layer is ineffective, and the other three layers are meaningless no matter how well they are done.

Charging handshake: threshold determines whether it can start or not

  • The control board uses PP/CC to check if the gun is properly plugged in and if the cable level matches. It also uses CP PWM to inform the vehicle of the upper limit of available current and confirm the status of the vehicle end.

  • Handshake failed, relay cannot be engaged.

  • Handshake is an admission condition for charging, but it is only a necessary condition, not a sufficient condition - by the way, even if the safety door has not passed, it still does not start.

Billing measurement: ledger, determining whether money can be collected or not

  • Specialized metering chips collect voltage, current, power, and electricity to provide a basis for billing, settlement, and carbon data verification.

  • Insufficient measurement accuracy, numerous billing disputes, and inability to pass subsidy verification.

  • The billing logic can be local or cloud based, but the measurement data must be reliably collected locally and saved in case of power failure.

Platform networking: extension, determining whether it can operate or not

  • Run OCPP through 4G, Wi Fi, or Ethernet to interact with the backend for authorization, remote start stop, fault reporting, OTA upgrades, and load scheduling.

  • Networking transforms a pile from a standalone device into an operational asset, but it manages policies and accounts and does not replace local security actions.

  • When the network is disconnected, local authorization, local reservation, full self stop, and security protection must still be able to run.

The relationship of four layers

  • Safe power outage is the root, charging handshake is the door, billing and metering are the accounts, and platform networking is the line.

  • The root cannot be broken, the door cannot jump, the account cannot be wrong, the line can be broken but there must be a local safety net.

  • The true value of the control board is to string these four layers into a closed loop locally: self check first, then handshake, passing through the safety door, closing the relay, continuous monitoring, abnormal disconnection, and recording and reporting.

Summary in one sentence:

  • The control board is responsible for handshake, billing, secure power outage, and platform networking. But safe power outage is the local hard bottom line, handshake is the starting threshold, metering is the basis for charging, and networking is an extension of operation. Four things are layered for collaboration, and safety is always prioritized.

The communication charging pile control board produced by Xincheng Technology is of high quality and good price. Welcome to inquire and purchase!

s