The core of optimizing the hardware protection design for the main control board of charging piles lies in establishing a comprehensive hardware protection system that integrates "defense + emergency" across four key dimensions: electrical safety, environmental adaptability, anti-interference, and redundancy fault tolerance.
Electrical Safety Protection: Blocking High Voltage and Abnormal Risks
Strengthen electrical isolation by using isolated transformers in power modules and pairing communication interfaces (CAN, Ethernet) with optocouplers or isolation chips to completely separate the high-voltage side from the low-voltage main control circuit, preventing high-voltage intrusion.
Configure a multi-level protection circuit with series-connected fast fuses (overcurrent), TVS diodes (overvoltage/surge), and PTC thermistors (overtemperature). The circuit rapidly disconnects in case of anomalies to prevent component burnout or fire.
Enhance insulation and withstand voltage performance, with a PCB creepage distance ≥8mm and clearance ≥6mm between high-voltage and low-voltage zones. Key areas should use flame-retardant insulating materials and pass the withstand voltage test (≥2.5kV AC, 1 minute).
Physics and Environmental Protection: Adapted for Complex Outdoor Scenarios
Optimize sealing, dustproofing, and waterproofing. The main control board housing adopts an IP65-rated sealed design, with waterproof connectors installed at the interface to prevent rainwater and dust intrusion, avoiding short circuits.
Enhance anti-tamper and anti-theft design by installing anti-tamper switches or one-time seals. These mechanisms trigger power shutdown or alerts upon unauthorized disassembly, preventing malicious modification of hardware parameters.
Enhanced vibration and impact resistance, with core components (chips, capacitors) adopting surface-mount packaging and secured with adhesive, while reinforced holes are added along the PCB board edges to accommodate scenarios such as charging pile transportation and outdoor installation.
Anti-interference Protection: Resisting Electromagnetic and Electrostatic Interference
Optimize PCB layout and grounding by strictly partitioning high-voltage circuits, power circuits, and main control circuits. Employ single-point or star grounding to minimize ground loop interference.
Install EMC filtering components, including a common-mode inductor and X/Y capacitors in series at the power input, and parallel termination resistors at both ends of the communication lines to reduce electromagnetic radiation (EMI) and electromagnetic sensitivity (EMS).
Configure ESD protection circuits by connecting ESD diodes in series with interface pins and reserving static discharge pads at the PCB edges, ensuring the ability to withstand ±8kV contact discharge and ±15kV air discharge static impact.
Redundancy and Fault Tolerance Design: Avoiding Single Points of Failure
Key circuits are redundantly backed up, with the core power supply adopting a dual-power design. Communication interfaces (e.g., CAN) reserve backup channels to prevent single-point failures from causing the main control board to fail.
Enhance fault detection and isolation by adding redundant sensors in series within the current and voltage sampling circuits. Use hardware logic to verify data consistency, automatically isolate faulty circuits, and trigger alerts in case of anomalies.
Xincheng Technology can comprehensively enhance the protection and safety of its produced AC charging pile main control boards through the aforementioned four dimensions of measures, safeguarding both users and equipment. Feel free to inquire and make a purchase!.
Contact:SHEN ZHEN X-CHENG Technology Co.,Ltd
Phone:18025316892
Tel:0755-21010929
Email:shutao.chen@x-cheng.com
Address:Room B911, Zhantao Technology Building, Longhua District, Shenzhen