We need to rewrite, and we can't just write one set.
Although the underlying mathematical logic of CP PWM duty cycle is similar, the standard definitions, grid parameters, and vehicle tolerance of different markets are combined, and the domestic mapping table is used to go global. For mild cases, current limiting and charging rejection may occur, while for severe cases, certification may not be possible.
Firstly, the mapping interval itself has regional differences.
IEC 61851 provides a general segmented formula for duty cycle to current, but the national and European standards are not completely consistent in terms of available and reserved segments.
Some default duty cycle intervals in domestic firmware may be interpreted as abnormal requests in European cars, leading to handshake failures.
The corresponding relationship of J1772 in North America is another set, with a narrower tolerance window.
The Japanese exchange station also has its own definition.
A set of mapping that hits the world is bound to go wrong in these markets.
Secondly, the local power grid parameters change the power conversion benchmark.
The essence of a mapping table is' duty cycle to current ', but users and platforms are concerned about power.
Middle East 230V, North America 240V, Japan 200V, the same duty cycle corresponds to completely different kW.
The main control board cannot write voltage and frequency to death, they must be used as runtime variables to participate in power upper limit calculation and display, otherwise there will be implicit non-compliance where the mapping is correct but the power is incorrect.
Thirdly, the tolerance of vehicle models varies and requires local verification.
The recognition threshold of CP voltage and duty cycle varies among the BMS of mainstream vehicle models in different regions, and is more pronounced during low temperatures or voltage fluctuations.
The mapping table not only needs to meet the standards, but also needs to be tested for handshake stability on mainstream local vehicle models, otherwise the standards are correct and the car cannot be charged.
The correct approach is to unify the kernel and configure it in layers.
The kernel retains the IEC universal segmentation formula as the mathematical foundation;
The configuration layer loads the duty cycle interval clipping rules, local voltage frequency parameters, and insertion gun standard types according to the target market;
The verification layer conducts interoperability testing for local mainstream vehicle models.
Load different configurations on the same main control board in different markets, instead of maintaining several unrelated sets of code.
Summary:
The IEC mapping table is a universal syntax, with each market having its own accent and measurement.
Going abroad requires rewriting, which decouples standard differences and grid parameters into configurable modules.
Only changing the gun head without rewriting the mapping, the car either cannot be charged, cannot be fully charged, or is judged as unqualified in the certification step.
The main control board of the communication charging pile produced by Xincheng Technology is of high quality and good price. Welcome to inquire and purchase!
Contact:SHEN ZHEN X-CHENG Technology Co.,Ltd
Phone:18025316892
Tel:0755-21010929
Email:shutao.chen@x-cheng.com